Operation CHARM: Car repair manuals for everyone.

Oxygen Sensor after Catalytic Converter, Bank 2






Oxygen Sensor after Catalytic Converter, Bank 2

Special tools, testers and auxiliary items required

Hose clamps up to 25 mm dia. (3094)

Ring spanner 7-piece set (3337) for oxygen sensor

Removing

All cable ties which are opened or cut open when removing, must be replaced in the same position when installing.

- Remove engine cover.

- Clamp off coolant hose - 2 - using hose clamps (3094) and pull off coolant hose.

- If necessary, seal connection using an appropriate plug.

- Remove coolant reservoir. - arrow -.





- Disconnect electrical wire from Engine Coolant Level (ECL) warning switch (F66) at bottom on coolant reservoir and set aside coolant reservoir with coolant hose - 1 - connected.

- Disconnect electrical connector - 4 -.





- Remove retainer for 4 electrical connections on bulkhead (to simplify removal and installation of oxygen sensor).

- Free up oxygen sensor wire up to oxygen sensor.

- Remove rear noise insulation.

- Remove oxygen sensor using tool (3337/5) and the extension (3337/6) from ring spanner 7-piece set (3337).





Installing

Tightening Specifications





Installation is in reverse order of removal, not the following:

New oxygen sensor threads are coated with an assembly paste. This paste must not contact sensor openings.

For a used oxygen sensor, only grease threads with hot bolt paste. This paste must not contact sensor openings; Hot bolt paste

During installation, all cable ties and clips on transmission must be reinstalled at the same location to prevent the oxygen sensor wiring from contacting the exhaust manifold.

Secure all hose connections using hose clamps appropriate for the model type: