Fuel Level Sensor 2, Checking, Right Lever Sensor
Greater than 1K Ohms there is aFuel Level Sensor 2, Checking, Right Lever Sensor
Special tools, testers and auxiliary items required
• Hand-Held Multimeter (V.A.G 1526D)
• Connector Test Set (V.A.G 1594C)
Procedure
- Remove the luggage compartment floor mat.
- Unbolt cover for right locking flange - arrows -.
- Disconnect electrical harness connector - 1 - at right locking flange.
• Ignore - 2 -.
- Connect multimeter between terminal - 2 - and - 4 - of connector - B - for resistance measurement.
• If measured value is 0 Ohms there is a short circuit. If measured value is Greater than 1K Ohms there is an open circuit in the wiring.
• To check resistance values "tank full" or "tank empty", the Fuel Level Sensor 2 (G169) must be removed. Refer to => [ Fuel Level Sensor 2, Right Lever Sensor ] Fuel Level Sensor 2, Right Lever Sensor and the sensor floater must be placed in upper or lower end position.
• With Fuel Level Sensor 2 (G169) removed, the following values are obtained because of the greater deflection of the floater arm: