Combination Valve, Checking
Combination Valve, Checking
Recommended Special Tools, Workshop Equipment, Testers, Measuring Instruments and Auxiliary Items
- V.A.G 1390 hand vacuum pump
Test Conditions
- Vacuum lines and hose connections free of leaks.
- Vacuum hoses not clogged or kinked
- Pressure hose for Secondary Air Injection (AIR) Pump Motor not clogged or kinked
Test Sequence
- Disconnect vacuum hose from combi-valve.
- Connect hand vacuum pump (V.A.G 1390 or VAS 6213 ) to vacuum hose -1- on combi-valve.
NOTE: Do not use compressed air during following check.
- Disconnect pressure hose at at Secondary Air Injection (AIR) pump motor -arrow- and blow air in with light pressure. Combi-valve must be closed.
- Operate the hand vacuum pump.
Combi-valve must open.
If the combination valve does not open or it is constantly open:
- Replace combi-valve.
- Erase DTC memory of ECM. Diagnostic Mode 04 - Erase DTC Memory
- Generate readiness code. Generate Readiness Code