Heated Oxygen Sensor and Oxygen Sensor Heater Before Catalytic Converter
Heated Oxygen Sensor and Oxygen Sensor Heater before Catalytic Converter
Special tools, testers and auxiliary items required
• Ring Spanner 7-Piece Set (3337)
Removing
- Remove engine cover. Refer to => [ Engine Cover with Air Filter Element ] Service and Repair.
- Disconnect electrical harness connector - 1 - of the heated oxygen sensor (G39) and oxygen sensor heater (Z19).
- Remove oxygen sensor - arrow - using tool from (3337).
Installing
When installing, note the following:
• New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.
• For a used oxygen sensor, only coat threads with hot bolt paste. This paste must not come into contact with sensor slots. Hot bolt paste, refer to the electronic parts catalog ETKA.
• Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.
• Tightening specification: 55 Nm