Accessory Assembly Bracket

Special tools, testers and auxiliary items required

Locking Pin (T10060 A)

Removing

All cable ties which are opened or cut open when removing, must be replaced in the same position when installing.


Observe safety precautions when disconnecting the battery.

- Remove tool formed insert under luggage compartment floor covering.

- Remove cover - arrow - for battery compartment





- Remove formed insert from over the battery.

- With ignition switched off, disconnect Battery Ground (GND) cable - arrow -.





- Remove center noise insulation fasteners - 1 to 3 -.





- Remove right noise insulation fasteners - 1 to 3 -.





- Disconnect secondary air hose at position indicated by - arrow -.





- Free up air hose to Secondary Air Injection (AIR) pump.

- Remove top mounting bolts for fan shroud - top arrows -.





Before removing the ribbed belt, mark the turning direction on it with chalk or a felt tip pen. A reversed direction of rotation can cause damage to the belt under operating conditions.

- Swing tensioning device in direction of - arrow - to relieve tension on the ribbed belt and then lock it in place using the (T10060 A).





- Remove ribbed belt.

- Free up coolant hose at bottom on fan shroud.





- Disconnect electrical connector - 3 - at secondary air injection (AIR) pump motor (V101) and free up electrical wiring.

- On vehicles with DSG transmission, remove coolant pipe bracket - 2 - to transmission oil cooler.

- Remove bolts - 1 -.

- Loosen bolt - 4 - and remove Secondary Air Injection (AIR) pump with bracket.

- Disconnect electrical harness connectors - 1 - for coolant fans at bottom on fan shroud.





- Remove mounting bolts for fan shroud at bottom - bottom arrows -.

- Pull out fan shroud downward with both fans.

- Disconnect electrical harness connector - 1 - for A/C clutch on A/C compressor and free up electrical wire.






The air conditioning refrigerant circuit must not be opened.

- Remove bolts - arrow - for A/C compressor.

- Securely tie the A/C compressor with connected coolant hoses at front on the longitudinal member.

- Remove electrical wire - 1 - on generator.





- Separate the electrical connector - 2 -.

Ignore - 3 -.

- Remove upper idler roller - 1 -.





- Remove mounting bolts - 2 - and - 3 - for generator.

Generator can be removed from bracket only with the upper mounting bolt still installed.

- Remove generator from accessory assembly bracket.

- Remove generator downward and to the left.

- Disconnect electrical connector - 3 - at after-run coolant pump (V51) - 2 - and remove pump with coolant hoses - 1 - and - 4 - connected downward from rubber loops on bracket. Spray rubber loops with silicone-free lubricant, if necessary.





- Remove bolts - 1 to 5 - and remove accessory assembly bracket.





Disregard - arrow -.

Installing

Tightening specifications, refer to => [ Ribbed Belt Drive Component Overview ] Ribbed Belt Drive Component Overview

Installation is in reverse order of removal, note the following:

Bolts - 1 - and - 2 - are fitting bolts.

- Next, hand tighten the bolts in sequence - 1 to 5 -.

- Then tighten bolts in sequence - 1 to 5 -.

- To make it easier to install the generator, drive the bushings for the retaining bolts back slightly.

- Install generator.

- Install A/C compressor.

- Install ribbed belt. Refer to => [ Ribbed Belt ] Ribbed Belt.