Oxygen Sensor After Catalytic Converter, Bank 2
Oxygen Sensor After Catalytic Converter, Bank 2
Special tools, testers and auxiliary items required
• Ring Spanner 7-Piece Set for Oxygen Sensor (3337 )
Removing
• All cable ties which are opened or cut open when removing, must be replaced in the same position when installing.
- Pull rear engine cover off - arrows -.
- Remove coolant expansion tank - arrow -.
- Disconnect electrical connection from engine coolant level warning switch (F66) at bottom of coolant reservoir and set aside coolant reservoir with coolant hoses - 1 - and - 2 - connected.
- Disconnect the electrical harness connector - 1 - for oxygen sensor 2 after catalytic converter (G131) and free up the wiring.
• Ignore - 2 -.
- Remove the oxygen sensor - 2 - with the ( 3337).
• To improve clarity, the removed engine is shown.
Installing
Installation is in reverse order of removal, note the following:
• Replace O-ring.
• New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.
• When reinstalling the previously used oxygen sensor, coat thread with hot bolt paste. Paste must not get on slits of sensor body.
• During installation, all cable ties must be reinstalled at the same location.
• Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.
Tightening Specifications