Refrigerant Circuit O-Ring Seals
Refrigerant Circuit O-Ring Seals
• Always use O-rings only once, replace.
• Coat O-ring seals with refrigerant oil before inserting.
• Make sure O-rings are seated properly on pipe or in groove.
• Perform work free of contamination (even the smallest deposit e.g. a hair, may lead to a leak).
• Install only O-rings that are resistant to refrigerant R134a and corresponding refrigerant oil. These O-rings are color-coded to avoid mistakes (currently "red", "light purple" and "dark purple").
• The O-ring dimensions - a - and - b - are different depending on installation location.
• In addition to the color-coded O-ring seals, use is also made at the factory of black O-ring seals for certain connections.