Ribbed Belt
Ribbed Belt
Removing
- Remove sound insulation by loosening securing pieces - 1, 2 and arrow -.
- Remove electrical harness connector - 2 - from bracket and disconnect it.
- Release retaining clip - arrow - and lay aside Coolant Fan Control (FC) Control Module (J293) - 1 -.
CAUTION!
Risk of destroying due to reversed running direction on a used ribbed belt.
• Before removing ribbed belt, marking running direction with chalk or felt-tip pen for reinstallation later.
- Pivot tensioning device in direction of - arrow - to relieve tension on ribbed belt.
- Remove ribbed belt and release tensioning device.
Installing
Installation is in reverse order of removal, note the following:
- Route ribbed belt - 2 - over belt pulley in specified sequence.
1 Generator
3 Idler roller
4 Vibration damper
5 Tensioning roller
• When installing the ribbed belt, ensure it is seated correctly on the pulleys.
- Start engine and check running belt.