Operation CHARM: Car repair manuals for everyone.

Version 1






Secondary Air Injection Combination Valves, Checking for Function and Leaks

Procedure

Hose connections properly sealed.

- Pull rear engine cover off - arrows -.





- Disconnect air guide hose - 3 - from Secondary Air Injection (AIR) combi-valve.





The left combination valve for Secondary Air Injection (AIR) is depicted in the illustration.

Ignore items - 1 and 2 -.

- Connect an assisting hose - arrow - to Secondary Air Injection (AIR) combi-valve.





- Blow into the assisting hose using light pressure (do not use pressurized air).

Secondary Air Injection (AIR) combination valve must be closed, it must not be possible to blow through.

- Blow into the assisting hose using higher pressure (do not use pressurized air).

The Secondary Air Injection (AIR) combination valve must open, it must be possible to blow through.

If the switching point is not recognized:

- Replace Secondary Air Injection (AIR) combi-valve. Refer to: Left => [ Secondary Air Injection Left Combination Valve ] Secondary Air Injection Left Combination Valve, right => [ Secondary Air Injection Right Combination Valve ] Secondary Air Injection Right Combination Valve.