Operation CHARM: Car repair manuals for everyone.

Right Fuel Delivery Unit With Fuel Pump






FSI Engines

Right Fuel Delivery Unit with Fuel Pump

Special tools, testers and auxiliary items required

Wrench (T10202)

Removing

Observe safety precautions. Refer to => [ Safety Precautions ] Fuel Supply System.

Observe rules for cleanliness. Refer to => [ Clean Working Conditions ] Fuel Supply System.


To remove the fuel delivery unit, the fuel tank may only be filled to a maximum of 1/3. Empty fuel tank if necessary. Refer to=> [ Fuel Tank, Draining ] Procedures.


Observe measures when connecting battery.

- With ignition switched off, disconnect Battery Ground (GND) cable - arrow -.





- Remove the luggage compartment floor mat.

To remove and install fuel delivery unit, remove vehicle tool kit and spare wheel from luggage compartment. It is then possible to sit or kneel in spare wheel well.

- Unbolt cover for right locking flange - arrows -.





- Disconnect electrical connectors - 1 - and - 2 - at right locking flange.





- Mark the fuel return line - 1 - and fuel supply line - 2 -.






Fuel system is under pressure! Before opening system, place clean rags around the connection. Then release pressure by carefully loosening the connection.

- Pull both lines from locking flange, by pressing the release buttons.

- Remove locking ring with Wrench (T10202).





- Pull off locking flange and remove the seal.





- Separate the electrical connectors - 1 to 3 - on the underside of the right locking flange.

To separate the line couplings that are mentioned later in the description, pull the fuel lines out of the fuel tank opening.





- Through the right fuel tank opening, separate the fuel supply lines - 1 - and - 2 - for the fuel delivery units by pressing the release buttons.

To improve clarity, the following illustration shows several components not installed.

- Unclip the filling line from the front of the right fuel delivery unit - arrow -.





- Unbolt cover for left locking flange - arrows -.





- Disconnect electrical connectors - 1 - and - 2 - at left locking flange.





- Remove locking ring with Wrench (T10202).





- Pull off locking flange and remove the seal.





- Separate the electrical connectors - 1 to 3 - on the underside of the left locking flange.

- Reach through the left opening in the fuel tank, press the release button and disconnect the connecting line - 1 -.





- Remove the connecting line on the right side of the fuel tank.

Ignore - 2 and 3 -.

- Reach through the right opening in the fuel tank, press the release button and disconnect the suction jet lines - 1 - and - 2 - for the left suction jet pump and for the right fuel delivery unit.





- Through the right fuel tank opening, press the release buttons - arrows - and remove the fuel delivery line - 2 - and the Fuel Level Sensor 4 (G393) - 1 -.





- Swing Fuel Level Sensor 4 (G393) aside to right.

- Press down both retaining clasps on the fuel delivery unit support - arrows -.





- Remove fuel delivery unit.

Be aware that fuel is still in the fuel delivery unit.

Installing

Tightening specifications. Refer to => [ Right Fuel Delivery Unit with Fuel Pump ] MPI Engines.

- Before installing the fuel delivery unit, pull the retaining clasps on the support upward until it engages - arrows -.





- Carefully press the fuel delivery unit into the support until it engages audibly.

- Insert the fuel delivery line - 1 - and the Fuel Level Sensor 4 (G393) - 2 - until it engages audibly on the right fuel delivery unit.





- Reach through the right opening in the fuel tank and attach the suction jet line - 1 - to the left suction jet pump and the suction jet line - 2 - to the right fuel delivery unit until they audibly engage.





- Reach through the left opening in the fuel tank and attach the connecting line - 1 - until it audibly engages.





- Connect the electrical connectors - 1 to 3 - on the underside of the left locking flange.





- Install the new locking flange seal dry.

- Insert locking flange in fuel tank, note installation position:





The tab - 2 - on locking flange must lie between tabs - 1 - and - 3 - on fuel tank.

- Tighten locking ring.





- Connect electrical harness connectors - 1 - and - 2 - to left locking flange.





- Fasten the cover for left locking flange - arrows -.





- Reach through the right opening in the fuel tank and attach the fuel lines - 1 - and - 2 - to the fuel delivery units until they audibly engage.





- Connect the electrical connectors - 1 to 3 - on the underside of the right locking flange.





- Install the new locking flange seal dry.

- Insert locking flange in fuel tank, note installation position:





The tab - 2 - on locking flange must lie between tabs - 1 - and - 3 - on fuel tank.

- Tighten locking ring.





- Install fuel supply line - 2 - and fuel return line - 1 - according to marking until they engage audibly.





- Connect electrical harness connectors - 1 - and - 2 - to right locking flange.





- Fasten the cover for right locking flange - arrows -.





- Connect battery. Observe safety precautions after connecting battery.

- After installing, fuel vehicle with at least 5 liters of fuel.