Ribbed Belt Pulley, With Freewheel
Ribbed Belt Pulley, with Freewheel
Special tools, testers and auxiliary items required
• Multi-Tooth Adapter (3400)
• 8 mm Hex Socket or T50 TORX
Removing
- Remove the generator.
- If present, press the protective cap off the pulley.
- Counter hold the pulley using the (3400) and rotate the generator shaft clockwise to loosen it.
Installing
Install in reverse order of removal, observing the following:
- Turn the generator shaft counterclockwise to tighten.
- Clip the protective cap onto generator pulley.
Tightening Specifications