Operation CHARM: Car repair manuals for everyone.

ACC Adjustment Device (VAS 6190), Converting for Adjustment Procedure






ACC Setting Device (VAS 6190), Converting for Adjustment Procedure

Special tools, testers and auxiliary items required

ACC Setting Device (VAS 6190)

Before performing adjustment, check in which mount the vertical slits on the (VAS 6190) are located. (VAS 6190) may have to be adapted before performing adjustment.

The (VAS 6190) must be adapted before adjustment procedure. If this is done during the adjustment procedure, the pre-calibration on the (VAS 6190) must be repeated.

- For the adjustment procedure, the vertical slits in mounts - 1 - through - 4 - must be inserted so that laser beam is approximately centered vertically when it contacts the sensor lens.






- The original nut at the top of the horizontal slits must be replaced with a standard nut - 3 -.






The original nut at the top of the horizontal slits must be replaced with a standard nut so that the mirror can slide far enough to the center.

- The mirror at the center - 1 - must be removed and installed again all the way to the left - arrow - near the vertical slits - 2 -.






- Then the mirror - 1 - must slide on horizontal slits as far as stop on vertical slits - 2 -.