Operation CHARM: Car repair manuals for everyone.

Evaporative Emission (EVAP) Canister Purge Regulator Valve N80 , Checking



Evaporative Emission (EVAP) Canister Purge Regulator Valve N80, Checking

Special tools, testers and auxiliary items required
- Multimeter.
- Wiring diagram.

Test requirements
- The Evaporative Emission (EVAP) Canister Purge Regulator Valve N80 fuse OK.
- The ignition switched off.

NOTE: Voltage for the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80 is supplied by the Engine Component Power Supply Relay J757.

Procedure







- Disconnect the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80 electrical harness connector - 2 -.

Checking internal resistance







- Using a Multimeter , check the resistance between terminals 1 and 2 of the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80.
Specified value: 22,0 to 30,0 Ohms.

If the specified value was not obtained:
- Replace the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80.

If the specification is obtained:

Checking voltage supply







- Using a Multimeter, check the electrical harness connector terminal 1 to 2 for voltage.
- Operate the starter briefly.
Specified value: battery voltage.

If the specified value was not obtained:
- Using a Multimeter, check the electrical harness connector terminal 1 to Ground (GND) for voltage.

Evaporative Emission (EVAP) Measure to
Canister Purge Regulator Valve
N80 Electrical Harness
connector Terminal

1 Engine Ground (GND)

- Operate the starter briefly.
Specified value: battery voltage.

If the specified value was not obtained:
- Check the wiring connection from the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80 electrical harness connector terminal 1 to the Engine Component Power Supply Relay J757 terminal 2/87 for an open circuit or short to ground (GND).
- Check the electrical harness connector for damage, corrosion, lose or broken terminals.
- If necessary, repair the wiring connection.

If the specified value was obtained:

Checking wiring
If the manufacturers test box is being used. Perform the following step.
- Install the test box.

If the manufacturers test box is not being used. Perform the following step.
- Remove the Motronic Engine Control Module (ECM) J623.







- Using a Multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve N80 electrical connector terminal 2 to the Engine Control Module (ECM) J623 electrical connector T60 terminal 5 for an open circuit.

Evaporative Emission (EVAP) Motronic Engine Control Module
Canister Purge Regulator Valve (ECM) J623 electrical
N80 Electrical harness connector T60 terminal
connector terminal or test box socket

2 5

Specified value: 1.5 Ohms.

If the specification was not obtained:
- Check the wiring for a short circuit to Battery positive (+) or an open circuit.
- Check the electrical harness connector for damage, corrosion, lose or broken terminals.
- If necessary, repair the wiring connection.

If necessary, repair the wiring connection.
- Replace the Engine Control Module (ECM) J623.

Final procedures
After repair work, the following work steps must be performed in the mentioned sequence:
1. Check the DTC memory.
2. If necessary, erase the DTC memory.
3. If the DTC memory was erased, generate readiness code.

- End diagnosis and switch the ignition off.