Fresh Air Blower and Evaporator Housing
Fresh Air Blower and Evaporator Housing
• The A/C unit may only be removed when the refrigerant circuit has been discharged. Bring the vehicle to a workshop that has the necessary tools and where the work can be performed by qualified personnel.
• Heating and A/C unit, removing and installing. Refer to => [ A/C Unit ] A/C Unit
1 Self-tapping screw
2 Cover
3 Screw
4 Air Flow Door Motor (V71)
• With Right Center Vent Motor Position Sensor (G113)
• Removing and installing, refer to => [ Air Intake Shroud with Air Flow Door ]
5 Connecting element
• Mark before removing risk of interchange
• Heed assignment code number "063")
6 Self-tapping screw
7 Air intake shroud
• Removing and installing, refer to => [ Air Intake Shroud with Air Flow Door ]
• Disassembling and assembling => [ Disassembling and assembling air intake shroud ]
• Seal the connections, refer to => [ Air Intake Shroud with Air Flow Door ] air intake shroud, removing and installing
8 Air flow doors
• Removing from intake housing.=> [ Disassembling and assembling air intake shroud ]
9 Bracket
10 10- Self-tapping screw
11 Self-tapping screw
12 Ring for air guide
• Left side
13 Air guide for fresh-air blower
14 Ring for air guide
• Right side
15 Fresh Air Intake Duct Temperature Sensor (G89)
• Removing and installing, refer to => [ Fresh Air Intake Duct ] Service and Repair
16 Bracket for fresh-air blower
17 Screw
18 Cover
• Seal connection between A/C unit and cover using black Silicone Adhesive Sealant (D 176 001 A3). Refer to => [ Recirculation Door Motor ] .
• A modified actuator cover with four bolting points instead of two. Refer to => [ Recirculation Door Motor ] , a modified cover with recirculation flap and a wiring harness with a modified grommet to the recirculation flap actuator were introduced from December 03 as a running change.
19 Control Motor Door Motor (V113)
• With Right Center Vent Motor Position Sensor (G143)
• Removing and installing, refer to => [ Recirculation Door Motor ]
20 Connecting element
• Mark before removing risk of interchange
• Heed assignment code number "064"
21 Cover
• Removing and installing, refer to => [ Cover with Recirculated Air Door ] Removal and Replacement
• Disassembling and assembling, refer to=> [ Disassembling and assembling cover ]
• Seal the connections, refer to => [ Cover with Recirculated Air Door ] Removal and Replacement and => [ Air Intake Shroud with Air Flow Door ]
• Removing recirculated-air doors from cover => [ Disassembling and assembling cover ]
• A modified actuator cover with four bolting points instead of two. Refer to => [ Recirculation Door Motor ] , a modified cover with recirculation flap and a wiring harness with a modified grommet to the recirculation flap actuator were introduced from December 03 as a running change.
22 Recirculated-air doors
• Removing from cover. Refer to => [ Disassembling and assembling cover ]
23 Self-tapping screw
24 Bracket
25 Cover
• For evaporator
• Seal the connections between the housing lower section and cover. Refer to => [ Evaporator ] Removal and Replacement
26 Fresh Air Blower (V2)
• Removing and installing, refer to => [ Fresh Air Blower ] Service and Repair
CAUTION!
Do not grasp fans of Fresh Air Blower (V2), force against fans or shifting balancing weights fastened to fans may cause imbalance and then problems during operation.
27 Bracket
• For wiring harness to Fresh Air Blower (V2)
28 Fresh Air Blower Control Module (J126)
• Removing and installing, refer to => [ Fresh Air Blower Control Module ] Fresh Air Blower Control Module
29 Grommet
• For sealing refrigerant line openings to evaporator in A/C unit
30 Evaporator
• Removing and installing, refer to => [ Evaporator ] Removal and Replacement
• With refrigerant lines, disconnecting and reconnecting. Refer to => [ Evaporator ] Removal and Replacement.
• With seal to A/C unit housing
31 Drip tray
32 Housing lower part
• With air distribution housing
• Disassembling and assembling, refer to => [ Bottom Half of Air Distributor Housing ] Bottom Half of Air Distributor Housing
• Air distribution housing, disassembling and assembling. Refer to => [ Air Distributor Housing ] Air Distributor Housing
Disassembling and assembling cover
A Screw
B Recirculated air door
C Shaft
D Bracket
E Screw
F Connecting element
G Cover different versions
Disassembling and assembling air intake shroud
A Screw
B Air flow door
C Shaft
D Bracket
E Screw
F Intake with seal to hood