Operation CHARM: Car repair manuals for everyone.

Airbag Adapter Vas 6036, Connecting



Airbag adapter VAS 6036, connecting







NOTE: The mechanic must electrostatically discharge him/herself before disconnecting ignition and ground (GND) wires (briefly touch closing wedge for door or body).

CAUTION: The airbag adapter VAS 6036 must remain connected to the seat until the seat is reinstalled.







1 - Seat connector power supply connector (red)
2 - Airbag adapter power supply connector (red)
3 - Airbag adapter connector (yellow)
4 - Airbag connector (yellow)
- Disconnect ignition and Ground (GND) wires.
- Connect airbag connector - 4 - to airbag adapter connector - 3 -.
- If present: Connect the airbag adapter power supply connector - 2 - to the seat connector power supply connector - 1 -.