Performing Final Control Diagnosis
Performing final control diagnosis
- Connect scan tool and select function "engine electronics".
- Press -> key.
Indicated on display (function selection):
- Press keys 0 and 3 for "Final control diagnosis" and confirm the entry with the Q key.
- Press the -> key until the following text appears:
Indicated on display (function selection):
- Confirm entry with the Q button.
The electric vacuum pump should now run for approx. 10 sec.
- Remove diagnosis lead from diagnostic connection.