Modular Wiring Routing With Corrugated Tubing on Front Seat
Modular Wiring Routing with Corrugated Tubing on Front Seat
Special tools, testers and auxiliary items required
- Trim removal wedge 3409
General information
With the introduction of modular wiring routing, the complete sheathing of the entire wiring harness with a fabric strap between the seat tray and the connectors to the connector station has been eliminated. A two-shell corrugated tubing in which the wires are routed separately has been implemented.
Opening corrugated tubing and removing individual wire
CAUTION: Observe safety precautions for work on airbags.
- Move front seat as far back and up as possible.
- Unclip connector station cover - 1 - under front seat.
- Use Trim Removal wedge 3409 to do this.
- Disengage cover - 1 - on corrugated tubing side.
- Release cable bracket - 2 - on connector station by pressing retaining tabs on both sides - arrows -.
1 - Wiring harness
3 - Corrugated tubing, two-shelled
CAUTION: Before handling airbag units (e.g. disconnecting electrical connector), the person handling it must "electrostatically discharge".This can be touching door striker, for example.
- Remove front seat.
- Attach seat to Fixture For Seat Repair VAS 6136.
- Using Trim Removal Wedge 3409, open cable bracket - 1 -.
- Remove cable bracket - 1 - from corrugated tubing - 2 -.
- Remove bolt - 1 -.
- Remove cable clip - 2 - from corrugated tubing - 3 -.
- Open fabric band - 2 - in area of - arrow -.
- Open corrugated tubing - 1 -.
Install individual wires and close corrugated tubing
Installation is reverse of removal. Observe the following when doing so:
CAUTION:
- Observe safety precautions for work on airbags.
- Before handling airbag units (e.g. disconnecting electrical connector), the person handling it must "electrostatically discharge". This can be done by touching door striker, for example.
- When bundling and placing individual wires in corrugated tubing, ensure wires are not twisted.
NOTE: Note installation position of two-part corrugated tubing to wiring harness and position of cable bracket to corrugated tubing.
- The beginning of the corrugated tubing - 4 - should be placed immediately after the clip - 2 - or cable tie.
- 3 - Wiring harness to connector station
- Ensure two-part corrugated tubing - 4 - locks cleanly over entire length.
- Ensure side - arrow A - of cable bracket - 1 - connects to the last rib - arrow B - on the corrugated tubing - 4 -.
- Bind transition of seat side of corrugated tubing - 1 - and wiring harness - 2 - with self-adhesive fabric tape - arrow -.
- Ensure that first the pins - A arrows - on cover - 1 - engage correctly in mounts - B arrows - on connector station - 2 -.
- They can only lock in the connector station when the cover is engaged correctly.