AIR Combination Valves - Version 2, Checking
AIR Combination Valves - Version 2, Checking
Special tools, testers and auxiliary items required
• Hand Vacuum Pump (VAS 6213)
Procedure
• Vacuum lines and hose connections free of leaks.
• Vacuum lines not plugged.
- Remove engine covers - arrows -.
- Remove the left and right vacuum hoses - 1 - and - 2 - on the combination valve being checked.
- Connect the Hand Vacuum Pump (VAS 6213) to the vacuum hose for the combination valve to be checked.
- Remove the front secondary air hose - arrow - from its bracket and disconnect it; to do so press the release buttons.
- Blow into the Secondary Air Injection (AIR) hose using light pressure (do not use pressurized air).
• Secondary Air Injection (AIR) combination valves must be closed, it must not be possible to blow through.
- Operate hand vacuum pump.
• The relevant combination valve must open, it must not be possible to blow through
- If the secondary air combination valve does not open, replace. Refer to: Left => [ Secondary Air Injection Left Combination Valve ] Secondary Air Injection Left Combination Valve, right => [ Secondary Air Injection Right Combination Valve ] Secondary Air Injection Right Combination Valve.
Assembling
Assembly is in reverse order of removal, note the following:
• Replace O-ring.