Right Front Heated Oxygen Sensor Before Catalytic Converter
Right Front Heated Oxygen Sensor before Catalytic Converter
Special tools, testers and auxiliary items required
• Ring spanner 7-piece set (3337)
Removing
• All cable ties which are opened or cut open when removing, must be replaced in the same position when installing.
- Separate electrical connector - 1 - for Mass Air Flow (MAF) sensor (-G70-).
- Disconnect air duct hose - 4 - at intake manifold.
- Unhook retainer for connections - 2 - and - 3 - at upper part of air filter housing.
- Remove bolts - arrows -.
- Remove upper part of right air filter housing.
- Remove air duct - 1 -.
- Remove the bolts - arrows -.
- Remove lower part of right air filter housing.
- Separate electrical connector - 8 - for Heated Oxygen Sensor (HO2S) (-G39-).
• Disregard the other items in the illustration.
- Expose electrical wiring to oxygen sensor.
- Remove Heated Oxygen Sensor (HO2S) (-G39-) - arrow 2 - using ring spanner set (3337).
Installing
Perform installation in the reverse order of removal, noting the following:
• New oxygen sensors are coated with assembly paste; the paste must not get into slots on the oxygen sensor body.
• When re-installing a used oxygen sensor, coat the threads with hot bolt paste. This paste must not come into contact with slots on oxygen sensor body.
• During installation, all cable ties must be re-installed at the same location.
• Wires of oxygen sensors must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.
Tightening Specifications