Operation CHARM: Car repair manuals for everyone.

Oxygen Sensor Heaters After Catalytic Converter, Checking






Diagnostic Procedures



Oxygen Sensor Heaters After Catalytic Converter, Checking

When servicing terminals 3 and 4 in harness connector of oxygen sensors, use only gold-plated terminals.

Special tools, testers and auxiliary items required

Hand multimeter (V.A.G 1526) or Multimeter (V.A.G 1715)

Test adapter kit (V.A.G 1594)

Wiring diagram

Test conditions

Motronic Engine Control Module (ECM) Power Supply Relay 2 (J670) -position 5- must be OK, check:

Battery voltage (both batteries) must be at least 11.5 Volts.

All electrical consumers such as, lights and rear window defroster must be switched off.

For vehicles with automatic transmission, selector lever must be in " P".

Parking brake must be engaged.

The Ground (GND) connections between engine and body must be OK.

Ignition switched off.

Fuses in right instrument panel fuse holder must be OK:

Right instrument panel fuse holder





Voltage Supply and Wiring to Control Module, Checking

Test sequence

- Disconnect corresponding 6-pin harness connector to oxygen sensor to be tested: Component location

- Connect multimeter to terminals 1 + 2 of connector to Engine Control Module for voltage measurement.





- Start engine and run at idle speed. Specification: at least 7.0 V

If specification is obtained:

- Switch ignition off.

- Erase DTC memory of Engine Control Module => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Modes 01 - 09, Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code => [ Readiness Code, Generating ] Monitors, Trips, Drive Cycles and Readiness Codes.

If specification is not obtained:

- Connect multimeter to terminal 1 of connector to Engine Control Module + Ground (GND) for voltage measurement. Specification: at least 11.0 V





- Switch ignition off.

If specification is not obtained:

- Check voltage supply at 4-pin connector terminal 1 to Motronic Engine Control Module (ECM) Power Supply Relay 2 (J670) according to wiring diagram:

- Erase DTC memory of Engine Control Module => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Modes 01 - 09, Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code => [ Readiness Code, Generating ] Monitors, Trips, Drive Cycles and Readiness Codes.

If specification is obtained:

- Check Ground (GND) activation of the respective oxygen sensor heater.