Variable Induction Position Sensor: Testing and Inspection
Intake Flap Vacuum Actuator, Checking
Only perform test if there were complaints about reduced torque, elasticity or engine power.
Special tools, testers and auxiliary items required
• Hand vacuum pump (VAS 6213)
Work procedure
- Start engine.
- Accelerate abruptly and observe linkage on back side of vacuum actuator when doing so.
• Linkage must move - arrow -.
- If linkage on vacuum actuator does not move, check the following:
• Vacuum system for leaks,
• Change over mechanism linkage for ease of movement,
• Vacuum hoses for correct connection,
• Vacuum hoses for leaks.
- If no malfunctions are found, remove vacuum hose on vacuum actuator.
- Connect hand vacuum pump (VAS 6213) to vacuum actuator connector - arrow - as shown in illustration.
- With hand vacuum pump, create vacuum and observe vacuum actuator linkage.
• Linkage must move - arrow -.
- Vent hand vacuum pump.
• Linkage must move back into output position.
• Check linkage movement sequence over entire adjustment range: it must move continuously without jerking.
- If linkage on vacuum actuator does not move or moves jerkily, replace actuator.