Ground Cable With Battery Monitoring Control Module (J367), From MY 09






Ground Cable with Battery Monitoring Control Module (J367), From MY 09

Special tools, testers and auxiliary items required

Pry Lever (80 - 200)

Removing

- Switch off ignition and remove ignition key.

TDI (SCR) vehicles

After the ignition is switched off, the reducing agent goes from the metering line to the Reducing agent injector (N474) and back into the reducing agent active chamber.

Wait until all the reducing agent has been returned before working in this area. This could take up to 10 minutes after switching off the ignition.

Only after this is complete can the battery be disconnected. Again, this could take up to 10 minutes after switching off the ignition.

- Remove screw - 2 - and pull floor vent - 1 - up.






- Remove the cover on the rear seat rail.

- Open the rear clips - 1 - - arrow -.






Use a screwdriver is necessary to remove the clips.

- Release retaining clamps on back side of cover - 1 - in - direction of arrow A -.






The seat is not shown in the illustration.

- Then remove cover in - direction of arrow B - from driver's seat console.

- Pry the covers - 1 - and - 3 - out of floor covering using the (80 - 200).






- Remove both front screws - 4 - on driver's seat console and tip console - 2 - up.

- Free up the wiring harness for the driver seat.

The seat is not shown in the illustration.

- Move the backrest and the seat surface forward with the driver seat folded.






- Remove cover - 2 - over battery by releasing retaining clamps - 1 - - arrow -.

Use a screwdriver is necessary to remove the clips.

- Loosen the nut several turns and remove the ground wire terminal clamp - 4 - from the battery terminal.






- Disconnect the electrical connector - 6 -.

- Remove the nut - 3 - and remove the ground cable - 2 - and grommet - 1 - out of the battery tray.

- Remove the Battery monitoring control module (J367) - item 5 -.

Installing






Install in reverse order of removal, observing the following:

If the connector on the battery monitoring control module comes loosen when connecting the battery, wait 30 seconds before connecting it again.

- Attach the ground cable battery terminal to the ground point and tighten the nut.

- Connect the ground wire terminal clamp 1 by hand to the battery negative terminal - and tighten the nut.

- Wait 30 seconds and then connect the connector to the battery monitoring control module.

- Install the bracket for the driver seat.

- Follow the instructions after connecting the battery. Refer to => [ Connecting ] Battery, Disconnecting and Connecting.

Tightening Specifications