Operation CHARM: Car repair manuals for everyone.

Ignition System: Testing and Inspection






Three Way Catalytic Converter, Checking

Test requirements

Battery voltage at least 12.5 volts.

Oxygen Sensors OK.

No leaks or damage to exhaust system.

Function test

- Perform the function test in Diagnostic Mode 06. Refer to => [ Diagnostic Mode 06 - Read Test Results for Specific Diagnostic Functions ] Diagnostic Mode 06 - Read Test Results For Specific Diagnostic Functions.

- End diagnosis and switch the ignition off.

If the specified values are exceeded:

- Check the exhaust system for leaks.

- If necessary, repair the leak in the exhaust system.

- Erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Mode 04 - Erase DTC Memory.

- Perform a road test to verify Repair.

If the DTC does not return:

Repair complete, Generate readiness code. Refer to => [ Readiness Code ] Monitors, Trips, Drive Cycles and Readiness Codes.

- End diagnosis.

If no leaks are found in the exhaust system:

- Replace the catalytic converter including front exhaust pipe.

Final procedures

After repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] Diagnostic Mode 03 - Read DTC Memory.

2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Mode 04 - Erase DTC Memory.

3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] Monitors, Trips, Drive Cycles and Readiness Codes.

End of Diagnosis