Battery, Visual Inspection
Maintenance-Free Batteries
Only maintenance-free batteries conforming to standards "TL82506 " (as of December 1997) and "VW75073" (as of August 2001) may be installed.
CAUTION!
Risk of injury due to contact with battery acid!
• Prior to handling or servicing batteries, read, understand and observe the Warnings and Safety Measures => [ There is a risk of injury from the battery
acid. ] Battery.
Risk of explosion due to the explosive gas that forms during battery charging.
• Observe warning notes and safety precautions => [ Risk of explosion due to the explosive gas
that forms during battery charging. ] Battery.
Battery, Visual Inspection
- Before performing extensive measurements, inspect visually.
• External battery condition;
• Battery connections;
• Secure battery seating.
CAUTION!
Risk of explosion, inadequate crash safety, risk of corrosion, shortened service life.
• A lose battery retaining bracket can damage the battery housing and allow battery acid to leak.
• A battery that is mounted incorrectly can sustain vibration damage resulting in damage to the battery plates.
• Tighten retaining bracket bolt.
Risk of malfunction in the electrical system or wiring burn.
• Wiring connection contact is not guaranteed if the battery terminals are damaged or the battery clamps are loose. Check the condition of the battery terminals; battery terminal clamp and auxiliary clamp tightening torque => Starting and Charging Starting and Charging.