Oxygen Sensors after Catalytic Converter
Oxygen Sensors after Catalytic Converter
Special tools, testers and auxiliary items required
• Ring Spanner 7-Piece Set (3337)
Removing
- Remove nuts - 1 - and - 2 - on right electrical connector bracket under vehicle floor.
• Ignore - 3 -.
- Remove cover and disconnect affected electrical connector.
1. Oxygen sensor (O2S) behind three way catalytic converter (TWC) (G130) with oxygen sensor (O2S) 1 (behind Three way catalytic converter (TWC)) heater (Z29)
2. Oxygen sensor (O2S) 2 behind three way catalytic converter (TWC) (G131) with oxygen sensor (O2S) 2 (behind Three way catalytic converter (TWC)) heater (Z30)
- Remove connector from bracket and free up electrical wire to affected oxygen sensor.
- Remove affected oxygen sensor with (3337/1).
1. Oxygen sensor (O2S) 2 behind three way catalytic converter (TWC) (G131) with Oxygen Sensor (O2S) 2 (behind three way catalytic converter (TWC)) heater (Z30)
2. Oxygen sensor (O2S) behind three way catalytic converter (TWC) (G130) with oxygen sensor (O2S) 1 (behind three way catalytic converter (TWC)) heater (Z29)
Installing
• Tightening specifications, refer to => [ Installed Location: Oxygen Sensors (O2S) Behind
Three Way Catalytic Converter, Tightening Specification ] Component Location Overview.
Installation is in reverse order of removal, note the following:
• Coat new oxygen sensors with an assembly paste.
• When reinstalling the previously used oxygen sensor, coat thread with hot bolt paste.
• Assembly paste or hot bolt paste must not get on slits in sensor body.
• Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.
• During installation, all cable ties must be installed at the same location.