Operation CHARM: Car repair manuals for everyone.

Oxygen Sensors after Catalytic Converter






Oxygen Sensors after Catalytic Converter

Special tools, testers and auxiliary items required

Ring Spanner 7-Piece Set (3337)

Removing

- Remove nuts - 1 - and - 2 - on right electrical connector bracket under vehicle floor.





Ignore - 3 -.

- Remove cover and disconnect affected electrical connector.





1. Oxygen sensor (O2S) behind three way catalytic converter (TWC) (G130) with oxygen sensor (O2S) 1 (behind Three way catalytic converter (TWC)) heater (Z29)

2. Oxygen sensor (O2S) 2 behind three way catalytic converter (TWC) (G131) with oxygen sensor (O2S) 2 (behind Three way catalytic converter (TWC)) heater (Z30)

- Remove connector from bracket and free up electrical wire to affected oxygen sensor.

- Remove affected oxygen sensor with (3337/1).





1. Oxygen sensor (O2S) 2 behind three way catalytic converter (TWC) (G131) with Oxygen Sensor (O2S) 2 (behind three way catalytic converter (TWC)) heater (Z30)

2. Oxygen sensor (O2S) behind three way catalytic converter (TWC) (G130) with oxygen sensor (O2S) 1 (behind three way catalytic converter (TWC)) heater (Z29)

Installing

Tightening specifications, refer to => [ Installed Location: Oxygen Sensors (O2S) Behind
Three Way Catalytic Converter, Tightening Specification ] Component Location Overview.

Installation is in reverse order of removal, note the following:

Coat new oxygen sensors with an assembly paste.

When reinstalling the previously used oxygen sensor, coat thread with hot bolt paste.

Assembly paste or hot bolt paste must not get on slits in sensor body.

Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.

During installation, all cable ties must be installed at the same location.