Operation CHARM: Car repair manuals for everyone.

Oxygen Sensors before Catalytic Converter






Oxygen Sensors before Catalytic Converter

Special tools, testers and auxiliary items required

Ring Spanner 7-Piece Set (3337)

Removing

- Remove air filter element. Refer to => [ Air Filter ] Air Filter.

- Remove air filter housing. Refer to => [ Air Filter Housing ] Air Filter Housing.

- Disconnect affected electrical connector.





1. heated oxygen sensor (HO2S) 2 (G108) before catalytic converter with oxygen sensor (O2S) 2 heater (Z28)

2. heated oxygen sensor (HO2S) (G39) before catalytic converter with oxygen sensor (O2S) heater (Z19)

- Free up electrical wire to affected oxygen sensor.

Ignore - 3 -.

- Remove affected oxygen sensor with (3337/1).





1. Heated Oxygen Sensor (HO2S) 2 (G108) before catalytic converter with oxygen sensor (O2S) 2 heater (Z28)

2. Heated Oxygen Sensor (HO2S) (G39) before catalytic converter with oxygen sensor (O2S) heater (Z19)

Installing

Tightening specifications. Refer to => [ Installed Location: Heated Oxygen Sensors (HO2S)
in Front of the Catalytic Converter, Tightening Specification ] Component Location Overview.

Installation is in reverse order of removal, note the following:

Coat new oxygen sensors with an assembly paste.

When reinstalling the previously used oxygen sensor, coat thread with hot bolt paste.

Assembly paste or hot bolt paste must not get on slits in sensor body.

Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.

- Install air filter housing. Refer to => [ Air Filter Housing ] Air Filter Housing.

- Install air filter insert. Refer to => [ Air Filter ] Air Filter.