Air Intake Housing With Fresh/Recirculating Air Door
Air Intake Housing With Fresh/Recirculating Air Door
Removing
- Remove the instrument panel and the instrument panel crossmember.
- Remove the heater. Refer to => [ Heater Unit ] Heater Unit.
- Remove bolts - A -.
- Remove the cover - B -.
- Disconnect connector - C -.
- Disengage air intake housing - D - from heater.
Installing
Reinstall all removed components in the opposite sequence while observing the following:
- When attaching air intake housing, make sure mounting points - E - and - F - are seated correctly.
- Install the wiring harness so that it cannot come in contact with any moving parts (for example, the actuating arm of the control motor).