Fuel Tank With Attachments, Overview, FWD
Fuel Tank with Attachments, Overview, FWD
1 Bolt
• 26 Nm
2 Securing Strap
• Locating point (hole) points in driving direction
3 Heat Shield for Fuel Tank
4 Vent Line
• White
• From EVAP canister to EVAP canister purge regulator valve 1 (N80)
• To disconnect, press release button on connection piece
• Clipped in on fuel tank
5 Fuel Line
• Black
• To engine
• To disconnect, press release button on connection piece
6 Vent Line
• Green
• From the leak detection pump (V144) to the engine
• To disconnect, press release button on connection piece
• Clipped in on fuel tank
7 Electrical Harness Connector
• For transfer fuel pump (G6) and fuel level sensor (G)
8 Bolt
• 8 Nm
9 Bracket
• Clip onto the protective plate
10 Protective Plate
• For fuel delivery connection
11 Collar Bolt
• 11 Nm
• Serves to secure fuel filler neck and Ground (GND) connection item - 14 -
12 Cap
• Attached to tank flap unit with fastening device
13 Gasket
• Replace if damaged
14 Ground (GND) Connection
• For discharging electrostatic charge
• Installed location
• Ensure connectors are securely seated and wiring is fastened with fuel filler tube collar bolt item - 11 -
• After installing, check the electrical connection of the metal ring on the fuel filler neck to a bare area of the chassis an using Ohm meter - Specified value: approximately 0 ohms
15 Vent Line
• From gravity valve to EVAP canister
• Clipped in on bracket in wheel housing
• To disconnect, press release button on connection piece
16 Fuel Tank
• Removing and installing, refer to => [ Fuel Tank with Attachments ] Fuel Tank With Attachments
17 Bolt
• 26 Nm
18 Lock Washer
• Turn toward left to remove
• Tighten to 2 Nm when installing.
Installation Position of Ground (GND) Connection
- Route ground (GND) connection as shown in figure.
- First, engage the ground (GND) connection contact - 2 - into the opening on fuel tank - 5 -. Then install the bushing - 1 -.
- Ensure connector of Ground (GND) connection - 4 - fits securely at metal ring - 3 - of fuel filler tube.
- Fasten wire contact of ground (GND) connection with collar bolt - arrow - for fuel filler tube.
After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter:
• Specified value: approximately 0 ohm.