Fuse Panel for Main Fuse
Fuse Panel for Main Fuse
Removing
- With ignition switched off, disconnect battery Ground (GND) wire.
- Remove plenum chamber cover rubber seal in - direction of arrow -.
- Remove plenum chamber cover - 1 - forward.
- Fold cover - 2 - to side and remove nut - 3 - at electrical wire.
- Remove nut - 1 - for fuse panel at positive pole.
Installing
Install in reverse order of removal, observing the following:
- Connect battery.
Tightening Specifications