Oxygen Sensor after Three Way Catalytic Converter (G130)
Oxygen Sensor after Three Way Catalytic Converter (G130)
Special tools, testers and auxiliary items required
• Ring Spanner 7-Piece Set (3337)
Removing
- Remove the rear engine cover - 2 - upward.
- Free up the fuel line - 4 - and hose connection - 1 - from the EVAP canister on the air filter housing and on the air guide tube.
- Remove the vacuum hose - 2 - from the air guide hose connection.
- Remove the air guide pipe by loosening the hose clamp - 3 - and opening the clips - arrows -.
- Remove the bolts - arrows -, remove the air guides - 1 - and - 2 -.
- Open the clips - arrows - and remove the air filter housing upper section.
- Disconnect the electrical connector - 2 - for the oxygen sensor after three way catalytic converter and free up the electrical wire.
• Ignore - 1 -.
- Remove the oxygen sensor - 1 - with the wrench (3337/1/2).
• To provide a better illustration, component location is shown from behind with engine removed.
Installing
Installation is performed in reverse order of removal, noting the following:
• New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.
• For a used oxygen sensor, only coat threads with hot bolt paste. This paste must not come into contact with oxygen sensor slots.
• Wiring connection of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.
• Tightening specifications, refer to => [ Oxygen Sensors Overview ] Oxygen Sensors Overview