A/C System Component Overview






A/C System Component Overview

HD = High-pressure end

ND = Low-pressure end





1 A/C Compressor Regulator Valve (N280)

Checking activation and function. Refer to => [ A/C Compressor Regulator Valve, Checking Activation Signal ] Testing and Inspection 1) => Servicing Refrigerant Circuit

2 Compressor

Removing compressor from bracket and re-installing in vehicles with 6 cylinder engine, 8 cylinder MPI engine or 8 cylinder diesel engine. Refer to => [ Compressor, Removing from Bracket, 6 Cylinder, 8 Cylinder MPI and 8
Cylinder Diesel ] Service and Repair 1) and => Servicing Refrigerant Circuit

Removing compressor from bracket and re-installing in vehicles with 12 cylinder engine. Refer to => [ Compressor from Bracket, 12 Cylinder ] Service and Repair and => [ ] Servicing Refrigerant Circuit

Compressor, removing and installing in vehicles with 8 cylinder FSI engine. Refer to => [ Compressor, 8 Cylinder FSI ] Service and Repair

Compressor, removing and installing in vehicles with 10 cylinder. engine. Refer to => [ Compressor, S8 10 Cylinder ] Service and Repair

When installing refrigerant lines/hoses and pertaining bracket, make sure there is a sufficient gap between belt, bracket and belt pulley

The type of compressor differs depending on the engine (6-, 8-, 10- or 12 cylinder. engine, diesel or gasoline engine

Different refrigerant oil capacities are designated depending on the compressor type ("6 SEU 14", "7 SEU 16" or " 7 SEU 17") and => Refrigerant R134a - Servicing

3 Compressor belt pulley/drive unit

Replacing compressor pulley 1). Refer to => [ Compressor Pulley, Version 1 ] Service and Repair

Ribbed belt, removing and installing.

Ribbed Belt Routing

Replacing compressor drive unit (vehicles with 8 cylinder. FSI or 10 cylinder engine). Refer to => [ Compressor Drive Unit ] Compressor Drive Unit

An overload safeguard is installed between the belt pulley and input shaft. It protects the compressor belt if the compressor seizes or does not move freely.

An overload safeguard is installed between the compressor drive unit and driveshaft to protect the engine chain drive if the compressor is seizes or does not move freely.

If compressor is runs with resistance, overload safeguard interrupts power transmission to compressor.

Rubber elements are installed between belt pulley/drive unit and compressor driveshaft, vibrations which may occur during compressor operation may be dissipated via these rubber elements (damper function at torque fluctuations).

Depending on compressor type, different belt pulleys are installed on compressor. Refer to=> [ Compressor Pulley, Version 1 ] Service and Repair

4 Oil drain plug

5 High pressure relief valve

6 Connection with valve

With the refrigerant circuit empty, use an adapter from the Socket for A/C Valves (T10364) to remove and install a valve insert.

CAUTION!
The valve insert may be removed only when the refrigerant circuit is empty.

7 High Pressure Sensor (G65) 1) => Servicing Refrigerant Circuit

Removing and installing, refer to => [ High Pressure Sensor ] Removal and Replacement

Checking signal, refer to => [ High Pressure Sensor, Checking Signal ] High Pressure Sensor, Checking Signal

8 Condenser

9 Cap

With seal

Always to be screwed on

10 Service connection

High pressure side

For measuring, discharging and recharging using service station.

To measure, drain and fill, bring the vehicle to a workshop that has the necessary tools and qualified personnel.

Different versions (with primary sealing valve or with Schrader valve) depending on refrigerant line, distinguishing characteristics.

To remove and install the service connection or the valve insert with the refrigerant circuit empty, use, for example, an adapter from the Socket for A/C Valves (T10364).

11 Bolts in refrigerant line

12 Restrictor

installed in threaded connection => [ 11 Bolts in refrigerant line ]

13 Evaporator

14 Service connection

Low pressure side

For measuring and discharging using service station.

To measure and drain, bring the vehicle to a workshop that has the necessary tools and qualified personnel.

Different versions (with primary sealing valve or with Schrader valve) depending on refrigerant line, distinguishing characteristics.

To remove and install the service connection or the valve insert with the refrigerant circuit empty, use, for example, an adapter from the Socket for A/C Valves (T10364).

CAUTION!
Only remove service connections when the refrigerant circuit is empty. The connection does not have a valve.

15 Cap

With seal

Always to be screwed on

16 Reservoir