Operation CHARM: Car repair manuals for everyone.

Service

1. Replace the radio and update the software of the MMI 3G system.

Tip: Refer to your parts department for the correct radio part number.

Tip: For successful results, the steps must be performed in this sequence.

2. Check MMI 3G system software version.

3. Update software of the MMI 3G system.

4. Perform feedback documentation to the SVM.

Check MMI 3G system software versions:

1. Switch on ignition and wait approximately 1 minute.





2. Press the SETUP and RETURN buttons simultaneously and hold both buttons down for about 5 seconds.





If the message in Figure 2 is displayed, the system is not completely initialized. Wait a few seconds and then press the RETURN button.





3. Read current MMI train (ZUG) version.





4. The train (ZUG) versions listed in the table above must be updated.

P versions are production build.
K versions are service updates.

Update MMI 3G systems software:

1. Connect an approved Audi battery maintainer/charger to vehicle.

2. Switch off all unnecessary electrical equipment (blower, seat heater, interior light, etc.).

Tip: Make sure that no electromagnetic interference sources, such as mobile phones, are operated in or near the vehicle while individual control units are being updated.

Tip: For complete and detailed instructions for the MMI 3G system update, refer to the attached instructions. (Note: The attached instructions are generic. Some portions may not apply to this specific TSB. Importing and exporting customer code data is not necessary for this MMI 3G update system.)

3. Insert update CD into the MMI 3G main (head) drive unit located in the center of the instrument panel.

4. Start the software update.

5. After the software update has been performed, confirm the "Abort (cancel) documentation" selection. The MMI 3G system will restart. Then perform the feedback documentation.

Perform feedback documentation using SVM:

1. Follow all instructions in the attached TSB 2011732 00 Software Version Management (SVM), operating instructions.

2. Confirm any proposed parameter settings and coding.

3. Perform test program "5F - Information electronics, resetting fault memory" to clear any faults in the system.

Tip: No control unit is flashed as part of the feedback documentation to the SVM. Do not perform any updates of control units. Do not replace any control units.





Warranty





Required Parts and Tools

Additional Information

The following Technical Service Bulletin will be necessary to complete this procedure:

^ TSB 2011732 00 Software Version Management (SVM), operating instructions.

All part and service references provided in this TSB are subject to change and/or removal. Always check with your Parts Dept. and service manuals for the latest information.

Attachment
































^ TSB 2011732 00 Software Version Management (SVM), operating instructions.