Spring Tensioning System VAS 6274 (VAS 6274), Converting
Spring Tensioning System VAS 6274 (VAS 6274), Converting
Special tools, testers and auxiliary items required
• Spring tensioning system (VAS 6274)
• Supplementary set (VAS 6274/10)
• It must only be converted once. It is not necessary to convert back again.
- Remove the tensioning system nuts - arrows - (quantity: 6).
- Remove the plate and remove the rods from the tensioning system.
- Remove the bolt - arrow - and the previous spring plate - 1 - with the hole - 2 - without the counterbore.
- Insert the new plate with the threaded holes from the supplementary set so the markings "R" and "L" are horizontal to the plate.
- Tighten the new plate with the new bolt - arrow - from the supplementary set. Do not rotate the plate.
- Insert the new spring plate - 1 - with the hole - 3 - with the counterbore from the supplementary set.
- Insert the new spring plate - 1 - so the stop - 2 - aligns with the marking "L".
- Tighten the new spring plate - 1 - with the new bolt from the supplementary set.
- Remove the spring plate at the hydraulic cylinder.
- Remove the tab - 2 - and replace with the new tab from the supplementary set.
- Tighten the new tab - 1 - with the new bolts - 1 - from the supplementary set.
- Install the spring plate lightly as far as the stop on the tensioning system and then rotate it back again slightly.
- Insert the new rods with the long taper - 1 - in the tensioning system plate.
- Insert the upper rod in the tab - 2 -.
- Position the plate on the rods.
- Install the sleeves - 2 - and - 3 - from the supplementary seat and install the nuts - 1 - lightly.
- Position the tensioning system on a level surface and tighten the nuts - arrows -.