Operation CHARM: Car repair manuals for everyone.

Spray Nozzle, Adjusting







Spray Nozzle, Adjusting

Special tools, testers and auxiliary items required

Setting Tool (T40187) equipped with Replacement Tips for T10127 (3125/5A)

Procedure

CAUTION!
Risk of injury.

If the (T40187) is not used, ensure that both sides are always covered and secured by covers - 3 - and - 4 -.

If one side is not secured by the cover, injury can be caused by the (3125/5A) - 1 - or adjusting pin - 2 -.

When opening each side, always ensure that the other side is not pointing toward the hand.







- Unlock the short cover - 1 - on the (T40187) - arrow A - and push it back - arrow B -.





- Adjust the spray nozzles with the (T10127) the fluid is sprayed onto the places shown on the rear window.





Dimension - a - = approximately 120 mm.

Dimension - b - = approximately 10 mm.

Dimension - c - = approximately 270 mm.

- If the spray field does not correspond to the specifications, clean dirty spray jet.

CAUTION!
Risk of injury.

The adjusting pin must be covered and secured by the cover after each use.

Cleaning the Nozzle

- Remove nozzle. Refer to => [ Spray Nozzle ] .

- Flush nozzle opposite to spray direction using clear water.

- To remove remaining impurities, the nozzle must only be blown out opposite to spray direction using compressed air.

- If the spray field still does not correspond to the specifications, replace the spray jet.