Spray Nozzle, Adjusting
Spray Nozzle, Adjusting
Special tools, testers and auxiliary items required
• Setting Tool (T40187) equipped with Replacement Tips for T10127 (3125/5A)
Procedure
CAUTION!
Risk of injury.
• If the (T40187) is not used, ensure that both sides are always covered and secured by covers - 3 - and - 4 -.
• If one side is not secured by the cover, injury can be caused by the (3125/5A) - 1 - or adjusting pin - 2 -.
• When opening each side, always ensure that the other side is not pointing toward the hand.
- Unlock the short cover - 1 - on the (T40187) - arrow A - and push it back - arrow B -.
- Adjust the spray nozzles with the (T10127) the fluid is sprayed onto the places shown on the rear window.
• Dimension - a - = approximately 120 mm.
• Dimension - b - = approximately 10 mm.
• Dimension - c - = approximately 270 mm.
- If the spray field does not correspond to the specifications, clean dirty spray jet.
CAUTION!
Risk of injury.
• The adjusting pin must be covered and secured by the cover after each use.
Cleaning the Nozzle
- Remove nozzle. Refer to => [ Spray Nozzle ] .
- Flush nozzle opposite to spray direction using clear water.
- To remove remaining impurities, the nozzle must only be blown out opposite to spray direction using compressed air.
- If the spray field still does not correspond to the specifications, replace the spray jet.