Selector Lever Cable
Selector Lever Cable
Special tools, testers and auxiliary items required
• Pry lever (80-200)
• Socket and key (T40031)
Removing
- Place the selector lever in the "D" position.
- Unclip the mounting frame for selector lever boot - 1 - from the center console and lift it upward and off - arrows -.
- Through the opening - arrow - in the shift mechanism, loosen the bolt on the selector lever cable approximately one turn using socket and key (T40031).
• Only loosen the clamping screw, do not remove it.
• The clamping screw is only accessible in the selector lever position "D".
• The selector lever must remain in the "D" position while the clamping screw is loose.
- Remove the rear crossmember bolts - arrows - crossmember.
- Remove the rear noise insulation by loosening the fasteners - 2 - and, if equipped the - arrow -.
- Remove front crossmember bolts - arrows - crossmember.
- Remove the driveshaft:
- Loosen the left and right floor panel covers on the inner side.
- Remove the heat shield - arrow -.
- Mark the installation position of the bracket for the selector lever cable.
- Press the selector lever cable ball joint - 1 - off from the selector shaft lever.
- Remove the bolts - arrow - for the selector lever cable bracket.
• Take care not to bend or kink the selector lever cable.
- Remove lock washers - 1 -.
- Remove the noise insulation - 2 - and slide forward.
• Disregard - items 3 and 4 -.
- Remove the selector lever circlip - 1 -.
- Remove the selector lever cable - 2 - from the shift mechanism.
Installing
Install in the reverse order, paying attention to the following:
• Replace the noise insulation locking washers.
• Lightly grease the eyelet and ball socket of the selector lever cable with polycarbamide grease (G 052 142 A2) before installing.
- Slide the noise insulation - 2 - over the opening on the selector lever cable - 3 -.
- Replace the O-ring - 1 - on the selector lever cable.
- Slide the selector lever cable - 2 - into the shift mechanism - arrow -.
- Secure the selector lever cable - 2 - with circlip - 3 -.
• Installation position: Angled end of circlip faces toward the shift mechanism.
- Secure the noise insulation to the shift mechanism with four new lock washers - 1 -.
- Install the selector lever bracket to the transmission according to the markings.
- Adjust the selector lever cable. Refer to => [ Selector Lever Cable Adjusting, from 12.05 ] Procedures.
- Check the shift mechanism. Refer to => [ Selector Mechanism Checking ] Procedures.
- Install driveshaft:
- Reconnect the exhaust system and ensure it is not under stress.
- Install the rear crossmember. Refer to => [ Tunnel Crossmember ] Tunnel Crossmember.
- Install the front crossmember.
Tightening Specifications