Pneumatic Line Repair
Pneumatic Line Repair
• A repair kit with pneumatic lines and line connectors is available for the repair of pneumatic lines. Refer to Parts Catalog.
• Pneumatic lines must not be disconnected directly at the components, only disconnection and connection according to the methods described below is permissible.
• Original replacement parts are delivered with short sections of line to which pneumatic lines with line connectors are connected.
• Protect pneumatic lines and line connectors from soiling.
• Heating the pneumatic lines to connect them to the line connectors is NOT permissible.
• The use of lubricant to connect the pneumatic lines to the line connectors is NOT permissible.
• The repaired pneumatic line is to be exactly as long as the previous line - tolerance +/- 10 mm.
• Dirt on the connecting points can cause leaks. Therefore, during tests, make sure the pneumatics and the measuring instruments remain clean.