Oxygen Sensors Assembly Overview
Oxygen Sensors Assembly Overview
Oxygen Sensor Electrical Connectors
1 EVAP canister purge regulator valve 1 (N80)
2 Oxygen sensor after three way catalytic converter (G130) and heater for oxygen sensor 1 after catalytic converter (Z29)
3 Heated oxygen sensor (G39) and oxygen sensor heater (Z19)
Oxygen Sensors
1 Oxygen sensor after three way catalytic converter (G130) and heater for oxygen sensor 1 after catalytic converter (Z29)
2 Heated oxygen sensor (G39) and oxygen sensor heater (Z19)
• Tightening specifications: 55 Nm
• New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.
• For a used oxygen sensor, only coat threads with hot bolt paste. This paste must not come into contact with oxygen sensor slots. Hot bolt paste.
• Always install the oxygen sensor wire in the same location so it does not come into contact with the exhaust pipe.
Heated oxygen sensor (G39) and oxygen sensor heater (Z19), Removing and installing, refer to => [ Heated Oxygen Sensor and Oxygen Sensor Heater before Catalytic Converter ] Heated Oxygen Sensor (G39) and Oxygen Sensor Heater (Z19).
Oxygen sensor after three way catalytic converter (G130) and heater for oxygen sensor 1 after catalytic converter (Z29), Removing and installing, refer to => [ Oxygen Sensor after Three Way Catalytic Converter and Oxygen Sensor 1 Heater ] Oxygen Sensor After Three Way Catalytic Converter (G130) and Oxygen Sensor 1 Heater (Z29).