Mirror Glass
Mirror Glass
Special tools, testers and auxiliary items required
• Pry Lever - Rmv Outside Mirror (80-200)
• Protective gloves
Removing
Injury risk.
• Wear protective gloves.
• Cover the area around the mirror housing with a soft cloth to protect the paint.
- Press the mirror glass - 1 - from the mirror adjusting unit using the (80 - 200) - arrow -.
- Disconnect the heated mirror electrical connectors - 2 - and - 3 - on the rear side of the mirror glass - 1 -.
- Unclip the electrical connector - 5 - from the bracket, if applicable.
- Disconnect electrical harness connector - 4 -.
Installing
Installation is reverse of removal, but note the following:
- Position the mirror glass on the mirror adjusting unit and press it on.
• Only press the center of the mirror glass when pressing it on.