ACC Setting Device (VAS 6190), Converting For Adjustment Procedure
ACC Setting Device (VAS 6190), Converting for Adjustment Procedure
Special tools, testers and auxiliary items required
• ACC Adjustment Device (VAS 6190)
• Before performing adjustment, check in which mount the vertical slits on the (VAS 6190) are located. (VAS 6190) may have to be adapted before performing adjustment.
• The (VAS 6190) must be adapted before adjustment procedure. If this is done during the adjustment procedure, the pre-calibration on the (VAS 6190) must be repeated.
- For the adjustment procedure, the vertical slits in mounts - 1 - through - 4 - must be inserted so that laser beam is approximately centered vertically when it contacts the sensor lens.
- The original nut at the top of the horizontal slits must be replaced with a standard nut - 3 -.
• The original nut at the top of the horizontal slits must be replaced with a standard nut so that the mirror can be slide far enough to the center.
- The mirror at the center - 1 - must be removed and re-installed all the way to the left - arrow - near the vertical slits - 2 -.
- Then the mirror - 1 - must be slide on horizontal slits as far as stop on vertical slits - 2 -.