A/C Compressor Drive Plate With Overload Protection, Checking Run-Out and Adjusting
A/C Compressor Drive Plate with Overload Protection, Checking Run-Out and Adjusting
Special tools, testers and auxiliary items required
• Universal Dial Gauge Mount (VW 387)
• Dial Gauge
Procedure
- Remove the A/C compressor. Refer to => [ A/C Compressor ] A/C Compressor.
- Clean the drive plate flange - A -.
- Secure the gauge - B - to the A/C compressor with the (VW 387) - C -.
- Attach the dial gauge probe - D - to the drive plate flange with a pre-tensioning of approximately 1.0 mm and set the gauge to "0".
- Turn compressor drive unit - E - a few turns.
• Target value for the run-out deviation: less than 0.21 mm.
• Maximum variance: 0.2 mm.