Throttle Valve Control Module
Throttle Valve Control Module
Removing
- Remove engine cover.
- Unclip the fuel supply line - 2 -.
- Loosen the clamps - 1 and 3 - and remove the right air guide pipe.
- Loosen the clamps - 1 and 3 - and remove the left air guide pipe.
- Remove the vacuum lines - arrows - from the intake connection.
- Remove the bolts - 4 - and remove the crankcase ventilation.
- Remove the hose - 2 - from the EVAP canister purge regulator valve 1 (N80).
- Disconnect the connectors - 1 and 3 -.
- Remove the EVAP canister purge regulator valve 1 from the bracket and move it to the side.
- Open the clamp on the intake connection.
- Remove both bolts - arrows - from the intake connection.
- Remove the intake connection.
- Remove bolts - arrows - and remove throttle valve control module (J338).
Installing
Installation is in reverse order.
• Tightening specifications, refer to => [ Intake Manifold Assembly Overview ] Intake Manifold Assembly Overview
Perform an adaptation using the vehicle diagnosis tester under guided functions after replacing.