Hood: Adjustments
Hood, Adjusting
Special tools, testers and auxiliary items required
• Adjusting Gauge (3371)
Hood Gap Dimensions
• Dimension - A - = 5.0 mm
• Dimension - B - = 4.5 mm
• Dimension - C - = 5.0 mm
• Dimension - D - = 3.0 mm
• Dimension - E - = 4.5 mm
Height Adjustment Stop Buffer
1 Adjusting Buffer
• Use for adjusting the height on the front side.
• The adjusting buffer - 2 - must lightly contact the lock carrier when the hood is closed.
2 Spacer
• The rubber buffers - 1 - function as a strike guard must not contact the lock carrier when the hood is closed.
3 Hood
4 Lock Carrier