Operation CHARM: Car repair manuals for everyone.

Air Distributor Housing Doors and Partitions






Air Distributor Housing Doors and Partitions

The air distribution housing cannot be disassembled. Refer to the Parts Catalog.

There are different versions of the air distribution housing depending on which A/C system is installed in the vehicle, "Comfort" or "Basis". Refer to the Parts Catalog.

Depending on the production date, there are different versions of the levers and connections on the A/C unit. Refer to => [ Air Conditioner, Levers and Connecting Elements ] Air Conditioner, Levers and Connecting Elements and the Parts Catalog.

Air Distribution Housing "Basis" A/C system






1 Air Distribution Housing "Basis" A/C System

Complete, do not disassemble

2 Left Housing Half

3 Right Housing Half

4 Lever

5 Door In The "Defrost" Vent

6 Shaft

7 Connecting Rod

8 Door In The Vent Leading To The Center Instrument Panel Vents

9 Vent Door Leading To The Left Instrument Panel Vent

10 Connecting Rod

11 Vent Door Leading To The Right Instrument Panel Vent

12 Vent Door Leading To The Front Left Footwell Vent

13 Connecting Rod

14 Vent Door Leading To The Front Right Footwell Vent

15 Lever

16 Lever

17 Lever

18 Vent Door Leading To The Rear Left Footwell Vent

19 Shaft

20 Vent Door Leading To The Rear Right Footwell Vent

Air Distribution Housing "Comfort" A/C System






1 Air Distribution Housing "Comfort" A/C System

Complete, do not disassemble.

Beginning 08.2007, as a running change, an A/C unit with an air distribution housing with optimized air flow will be introduced (versions "1" and "2"). Refer to => [ Comfort A/C Unit and Air Distribution Housing ] Comfort A/C Unit and Air Distribution Housing.

2 Left Housing Half

3 Right Housing Half

4 Upper Housing For Vents

5 Lever

6 Lever

7 Door For Left Indirect Ventilation Vent

8 Door In The "Defrost" Vent

9 Door For Right Indirect Ventilation Vent

10 Lever

11 Lever

12 Vent Door Leading To The Left Instrument Panel Vent

13 Vent Door Leading To The Front Left Footwell Vent

14 Lever

15 Lever

16 Vent Door Leading To The Rear Left Footwell Vent

17 Lever

18 Vent Door Leading To The Right Instrument Panel Vent

19 Vent Door Leading To The Front Right Footwell Vent

20 Lever

21 Lever

22 Vent Door Leading To The Rear Right Footwell Vent

23 Shaft

24 Shaft

25 Connecting Rod

26 Connecting Rod

27 Connecting Rod

28 Connecting Rod

29 Separator Wall

If the air flow to the front and rear vents is separated from each other; the requirement for different front and rear air temperatures (depends on the setting of each temperature door ).

30 Grommet

Glued in the separating wall, item 29=> [ (Item 29) Separator Wall ]

31 Grommet

Glued in the separating wall, item 29 => [ (Item 29) Separator Wall ]

32 Door In The Vent Leading To The Left Center Instrument Panel Vents

33 Door In The Vent Leading To The Right Center Instrument Panel Vents

34 Separator Wall

If the air flow to the left and right vents is separated from each other; the requirement for different front and rear air temperatures (depends on the setting of each temperature door ).

35 Vent Door Leading To The Rear Right Center Console Vent

36 Vent Door Leading To The Rear Right Center Console Vent