Cold Start Injector: Testing and Inspection
REMOVING AND INSTALLING COLD START VALVERemoving and Installing:
- Pull off plug (1).
- Disconnect fuel line (2).
- Unscrew screws.
- Take off cold start valve.
Installation Note:
- Check code number (1).
- Replace seal (2).
Checking:
- Unscrew cold start valve on intake manifold.
- Fuel line remains connected.
Checking - L-Jetronic - E 30:
- Unscrew cold start valve on intake manifold.
- Fuel line remains connected.
- Pull off fuel pump relay (1).
- Bridge terminals 87b and 30 with Special Tool 6 13 050.
- Fuel pump runs.
Leak Test:
- Check permissible leak rate.
Checking Fuel Flow Rate and Spray Angle:
- Hold cold Start valve in measuring glass 1 33 020.
- Plug Jetronic test lead 6 11 440 on cold start valve and connect with B + and B -.
- Check fuel flow rate and spray angle (1).