Suspension Control ( Automatic - Electronic ): Service and Repair
- Switch on ignition.
- Pull off cable from low pressure switch and link cable terminals.
- Detach control rod and push control switch lever into "discharge" position, i.e. towards the front.
- After 20 seconds the system will be depressurized.
After Fitting
- Connect cable to low pressure switch.
- Switch on ignition.
- Push lever into "Lift" position and wait until the high pressure switch stops the pumping process.
- Attach control rod.
- Top up hydraulic fluid reservoir. It is not necessary to bleed the system.