Symptom Related Diagnostic Procedures
Control Unit Connector:
Incorrect temperature setting.
- Check the entire linked sensor circuit (with the ignition switched off).
- Disconnect 12-pin plug (1) from the control unit.
- Connect an ohmmeter to the plug between terminals 4 and 12.
Temperature/Ohms Chart:
Temperature/Ohms Chart