Removing and Installing 0C (32F) Temp. Switch
REMOVING AND INSTALLING 0°C(32°F) TEMPERATURE SWITCH- Pull off plug (1).
- Unscrew temperature switch.
Installation Note:
- Tightening torque: max. 30 Nm (22 ft lbs.).
Installation Note:
- Check code number (1) and switching temperature (2).
Checking:
- Connect ohmmeter (M 06) on temperature switch.
- Ohmmeter must display approximately 0 ohm for temperature < -8°C (+18°F).
- Ohmmeter must display approximately infinite ohms for temperature > 4°C (39°F)