Replacing Evaporator Temperature Regulator
- Disconnect battery ground lead.
- Unscrew bolts.
- Place trim panel in footwell.
- Pull evaporator temperature regulator (1) off of plug (2).
Connections of Multiple Pin Plug
Numbers are located on back of plug receptacle.
1 = brown
3 = blue/yellow
4 = green/yellow
5 = black
6 = white
- Reverse procedure to install.