Fuel Pump Relay (DME Relay 1)
Fuel pump relay (DME relay 1):Check function:
•D• 100 - This status inquiry is only possible in the case of DME M1.3. The EKP relay must switch on during start or engine operation. (Display: ON).
Possible causes:
- Wire to DME control unit Pin 3 defective
- Relay 1 or voltage supply not OK
- Voltage supply for DME control unit not OK
- No signal from engine speed/position pulse generator
- The control unit is defective if not ground potential is output at DME control unit Pin 3 during start and engine operation although the above points are OK.