Component Tests and General Diagnostics

1. Remove the air flow meter harness connector and measure continuity between the following terminals at the meter electrical connector (male plug). Measure between pins:

41 and 14 = Continuity If not, replace the air flow meter.
41 and 59 = Continuity If not, replace the air flow meter.

2. Reconnect the air flow meter harness connector and remove the insulating cover from the rear of the connector.
3. Turn the ignition switch to the RUN position.
4. Measure the voltage between gray/yellow wire (terminal 2) and ground while moving the intake air flap manually.

Voltage should vary smoothly between approximately 0.5 and 4.5 volts. Sharp intermittent variations indicate shorts or corrosion.

NOTE: Voltage does not increase in linear fashion.

If the correct measurement is not obtained or the flap sticks or binds in the meter, replace the air flow meter.